pH Simulators will help you to
easily troubleshoot problems with your pH control system.
Quickly identify which component in the system is causing your
difficulty.
|
 |
PRODUCT FEATURES
|
pH control loops can be difficult to
troubleshoot, unless you have the right tools.
For years, the typical customer when faced with a pH error on his
display will replace the old pH electrode. The old probe is
tossed it into the trash, and a fresh electrode installed. If
this solved the problem, all is well.
If the user does not have a spare probe on hand, a new one may
have to be shipped overnight at considerable expense. If the
replacement probe does NOT solve the problem, time and money has
been wasted.
The Sensorex pH
checker simulates a perfect pH electrode. The technician
selects a pH signal
(4, 7 or 10) and connects the simulator
to the cable assembly.
How the Simulator Can
Help
If the controller displays the
correct value, the electrode is bad, and needs to be replaced.
If there is still an error on
the display, another system component is at fault, and the checker
will help you to determine which one is bad.
The simulator may be connected
directly to the preamplifier, and the signal verified. if this
solved the problem, the cable between the electrode and the
preamplifier may be the culprit.
If the simulator is connected
to the cables leaving the pre amp and the display is normal, the
preamplifier needs to be checked. Maybe a loose cable
connection on the terminal strip, a bad cable, or a bad
preamplifier.
if the simulator is connected
directly to the controller, and the display still shows error, it
may be time to service the controller.
The simulator costs less than
most pH electrodes. It can easily pay for itself the very first time
you consider disposing of a perfectly good pH electrode.
You will be able to eliminate
the electrode, cable, meter, preamplifier, or controller as the
cause of the problem.
You may also check under high impedance
condition, a most useful option with our checkers.
C110 pH Simulator
The Model C110 Checker/Simulator verifies pH, and also
incorporates +/- 700 mV outputs to verify ORP/REDOX instruments.
This is an ideal unit for full pH and ORP/REDOX field trouble
shooting. The compact case uses a water-resistant rubber key
pad that feels nice to the touch.
Impedance loaded
or no load signals may be generated with this unit.
Included with the checker is a CX2 interconnect cable with BNC
connector. Accessory Model CX2 cables with a wide
variety of connectors are sold separately). Order your C110
Simulator today.
|