Made with special limits-of-error material for better accuracy
Standard insulation provided with 304 and 316 SS sheaths, high
purity insulation provided with Inconel 600 sheath
Maximum continuous operating temperature for the standard
transition is 350°F (177°C). A high temperature transition 900°F
(482°C) maximum can be provided by ordering Special Requirement
Option H in Box 11
Standard lead wire termination is 3/4” stripped leads
.063” to .125” O.D. thermocouples use 24 gauge lead wire and
.188” to .375” O.D. thermocouples use 20 gauge lead
wire