The Signet 2552 Magmeter Flow Sensor is a heavy duty, high
performance sensor in an adjustable-insertion configuration
that can be used with a ball valve for hot-tap installations.
This insertion style flow sensor has no moving parts and is
constructed of corrosion-resistant materials to provide
long-term reliability with minimal maintenance costs.
The 2552 is versatile and simple-to-install,
delivering reliable flow measurement over a wide dynamic range
in pipe sizes ranging from DN50 to DN1200 (2 to 48 inches).
Signet 2552 Magmeters offer a variety of output options
compatible with Signet flow instrumentation that feature a
frequency or digital (S3L) input. The blind
transmitter (4 to 20 mA output) or digital sensor interface is
available for long distance signal transmission.
The
empty pipe detection features a zero flow output when the
electrodes are not completely wetted. The frequency output is
bi-directional while the 4 to 20 mA output can be set for uni-
or bi-directional flow. The 4 to 20 mA output is factory
spanned and can be changed using the PC compatible accessory
set-up tool.
|