HAVE A QUESTION -
CALL:
800 284 9698 OR
760 438 0890
Oxygen Measurement Using a Zirconia Sensor.
O2 is an important parameter to measure and control in kilns and furnaces. The
diagram below shows the Tiger 320 Series DI-50 controller connected to a
Zirconia O2 sensor with a built-in thermocouple.
The controller calculates the O2 level from the temperature and mV level of
the sensor. The result is then displayed on the controller.
The Tiger provides a reliable, cost-effective solution, enabling even very
small boilers to be upgraded to reduce pollution and save on fuel costs.