The Fuji Electric Time Delta-C ultrasonic flow meter is the latest
generation of high performance ultrasonic liquid flow meters using
transit-time technology. As it is a non-invasive clamp-on ultrasonic flow
meter, the Fuji Electric Time Delta-C ultrasonic flow meter is the perfect
option for measuring flow rates of relatively clean, homogeneous liquids
in closed, filled pipes. The Fuji Electric Time Delta-C ultrasonic flow
meter is particularly effective in applications where high accuracy is
required and the flow meter needs to be installed without shutting down
the process.
The Fuji Electric Time Delta-C ultrasonic flow meter uses advanced
digital signal processing technology to provide a compact, lightweight
solution with accuracies that are better than ±1% of flow rate with
minimal influence by the pressure or temperature of the measured fluid.
The Fuji Electric Time Delta-C ultrasonic flow meter offers best-in-class
anti-bubble performance, which allows for accurate readings with air
bubble content as high as 12% volume at 3 ft/s velocity.
The rugged construction of the Fuji Electric Time Delta-C ultrasonic
flow meter makes it ideal for installation in internal and external
environments where IP66 (NEMA 4) protection is required. By utilizing the
latest technologies, the Fuji Electric Time Delta-C ultrasonic flow meter
is just 2/3 the size of its predecessor, the Time Delta-S.
Configuration of the Fuji Electric Time Delta-C ultrasonic flow meter
is simple and intuitive via push buttons on the front panel.
Alternatively, free PC compatible software is available, allowing multiple
configurations to be stored and downloaded from a PC to the Fuji Electric
Time Delta-C ultrasonic flow meter. Real-time trending and data logging as
well as diagnostics can be performed with the loader software. The
software also includes a Sensor Spacing Calculation tool. Where flow rates
and totals need to be transmitted, the Fuji Electric Time Delta-C
ultrasonic flow meter provides a selection of outputs which include
4-20mA, relay, transistor outputs, RS232 and RS485(Modbus).
The Fuji Electric Time Delta-C ultrasonic flow meter requires clamp-on
sensors. These sensors clamp to the outside of pipes and cover pipe
diameters from 13 to 6000mm (0.5 to 235 inches) at liquid temperatures
from -40 to 200°C (-40 to 390°F). The system requires a straight pipe run
of 10x and 5x pipe diameters upstream and downstream respectively.
Benefits of the Fuji Electric Time Delta-C Ultrasonic Flow Meter:
- No system downtime for installation
- No system contamination
- Superior anti-bubble performance
- Non-invasive set-up with no moving parts
- Minimal influence by the pressure or temperature of the measured
fluid
Transit Time Ultrasonic Flow Meters – Technology Explained
Transit Time ultrasonic flow meters such as the Fuji Electric Time
Delta-C are well-suited for relatively clean fluids with low to moderate
aeration. These meters operate by comparing the time for an ultrasonic
signal to travel with the flow (downstream) against the time for an
ultrasonic signal to travel against the flow (upstream). The difference
between these transit times is proportional to the flow, and the flow
meter converts this information to flow rate and total. With this
technology, the transducers are mounted on the outside of the pipe,
providing tremendous advantages over more traditional and invasive flow
measurement instruments. This product is virtually maintenance free.
|
Quick Specs
-
Manufactured by
Fuji
Electric
-
NEMA 4 (IP66) rating (optional NEMA6/IP67)
-
Fluid sound velocity: 300-2500 m/s
-
Accurate to ±1.0% of rate
-
Superior anti-bubble performance
-
Compact and lightweight transmitter
-
Communications: RS232C or RS-485 MODBUS (optional)
-
Pipe diameter range: 13mm to 6000mm (0.5 to 235")
-
Quick response: 0.2 sec. or less (quick response mode)
-
Advanced digital signal processing
-
Fluid turbidity: 10000mg/L max.
-
Flow velocity range: 0 to ±32 m/s (0 to ±1.5 ft/s)
-
Power supply: 100 to 240VAC or 20 to 30VDC (optional)
-
Back-lit LCD with 2 lines of 16 character each
-
Display includes flow velocity, bi-directional rate and total
-
Analog output: 4-20mA DC
-
Digital output: (1) relay and (2) open collector transistor outputs
-
Digital input: dry contact (optional)