Breakthrough technology
for Peristaltic Pumps.
The TFD system will detect a wide range
of chemicals (i.e. chlorine, acids, soaps, etc.). This unique
technology was designed to ignore pump friendly fluids; such as
water condensation and
lubricants.
Download the
TFD data
sheet
for more details. (PDF file)
How does it work?
If a chemical is detected in the
pumphead (by tube failure), the pump will
automatically shut off and energize a relay, permitting
communications with external equipment, such as an alarm or a
SCADA system. The chemical must be cleaned from the pump head
and the tubing should be replaced before the pump will start
again.
-
The TFD system ships
as standard on our most popular peristaltic pump models.*
No extra cost to you.
-
The sensors are located within the
pumphead. Sensors are constructed of chemical
resistant Hastelloy-C.
-
Only Blue-White offers this
technology. Patent No.
7,001,153
*Excluding A-100NX and
A-1600 models
|