The Blancett Frequency-to-Current (F-to-I) and Frequency-to-Voltage
(F-to-V) converters are microprocessor-based devices designed to provide
an analog output directly from a Blancett turbine flow meter. The
converters measure and calculate the flow rate of a turbine flow meter and
produce an analog output representative of that flow rate, in the form of
a 4-20 mA or 0-5 VDC signal. If a converter is ordered with a flow meter,
the two components ship from the factory calibrated as a system. If the
converter is a replacement, the turbine meter's K-factor has changed, or
the converter is being used with some other flow meter, then
re-programming is possible with an optional Windows®-based software
utility. The F-to-I and F-to-V converters were designed for use with
Blancett flow meters, but in many cases they may be configured for use
with other turbine meters. Please consult Instrumart for details.
F-to-I Coverter Specifications
- Power Supply: Loop-powered 6 volt maximum insertion
loss
- Power Consumption: 25 mA maximum
- Frequency Range: 0-3500 Hz
- Analog Output: 4-20 mA
- Operating Temperature: -22 to 158°F (-30 to 70°C)
F-to-V Coverter Specifications
- Power Supply: 10-30 VDC
- Power Consumption: 10 mA maximum
- Frequency Range: 0-3500 Hz
- Analog Output: 0-5 VDC
- Operating Temperature: -22 to 158°F (-30 to 70°C)
This product is an accessory for the following products: |
- Manufactured by
Blancett
- Converts turbine pulse output into linearized analog output
- Choice of 4-20 mA or 0-5 VDC output
- Microprocessor-based device
- Enables integration with data acquisition devices
- Two mounting styles available for ease of installation
|